ESA612 Electrical Safety Analyzer

One-touch Testing with ECG
This product has accessories available to purchase online now. See listing in Accessories tab below.

The ESA612 combines the power of a ECG simulator and electrical safety analyzer in a single rugged portable device. The ESA612 includes two electrical safety test load selections for global use, as well as one-button access to multiple applications.

ESA612 Electrical Safety Analyzer

The power of a ECG simulator and electrical safety analyzer in a single rugged portable device.

The ESA612 Electrical Safety Analyzer represents over 20 years of Fluke Biomedical experience in test equipment for biomedical and clinical engineering professionals that perform field service on medical equipment throughout their facilities, in clinics, and anywhere onsite service is required. Portable, lightweight, and designed for operation in tight spaces, the ESA612 offers the functionality of a simulator and electrical safety tester in a single test tool. With the selection of two test loads, this versatile product can be used worldwide for compliance testing to preventative maintenance electrical safety standards of choice. The versatility of the multifaceted ESA612 Electrical Safety Analyzer is further expanded with optional automation software, which speeds and simplifies testing and provides high-end-analyzer productivity at software-level investment. Ansur-automated ESA612 standardizes test procedures, compares results to standards limits, and generates and stores reports for total digital data management.

Key Features

  • Portable, ergonomic and lightweight
  • Large, easy-to-read display with adjustable contrast
  • User-friendly interface
  • Tilt stand for stand-up testing in field environments
  • Five applied parts jacks and easy ECG snap connection with optional expander box
  • ECG waveform tests and dual-lead measurements combine the functionality of a simulator and safety analyzer in a single test tool
  • Internal memory for 100 test records
  • Replaceable mains fuses keep your unit in the field and out of the repair shop
  • Two-year extended warranty (no-cost, available after first-year calibration at the Fluke Biomedical Cleveland Service Center)
  • 20 A at 120 V current capability
  • USB connection for use with Ansur and Data Viewer software (for memory download to PC) to standardize Test procedures, compare results to standards limits, generate and store reports and perform total digital data management
  • Rigorously tested for rugged field applications, with CE and CSA in addition to the Fluke-quality-design stamp of approval

All models include:

  • Getting Started Guide, hard copy, multilingual (MANUAL)
  • Ansur Plug-in, CD with demo version (CD-ROM)
  • Data Transfer Cable (CABLE ASSEMBLY)

Accessory Kits include:

  • Test Lead Set
  • TP1 Test Probe Set
  • AC285 Alligator Clip Set (ESA T/L KIT, specific to country)
  • Null Post Adapter (ESA620-NPA)
  • 5-to-5 Banana Jack to ECG (BJ2ECG)
  • Adapter (ESA612-2016)
  • Carrying Case (9530-0075)
  • Power Cord Specific to country (specific to country)
Model NamePart NumberDescription
ESA612-14-DEN5276073ESA612-14-DEN, 250V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord DEN
ESA6124132173ESA612 US, 115 V Includes all of the above items. USA Accessory Kit specific details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord US (LINE CORD)
ESA612-014132186ESA612 France/Belgium, 230 V Includes all of the above items. Accessory kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord Europe (75026)
ESA612-024132199ESA612 Europe, 230 V Includes all of the above items. Accessory kit details: Alligator Clip Set (ESA T/L KIT EUR) Power Cord Europe (75026)
ESA612-034132208ESA612 Israel, 230 V Includes all of the above items. Accessory kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord Israel (LINE CORD)
ESA612-054132213ESA612 Australian, 230 V Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord Australian (75025)
ESA612-064132224ESA612 UK, 230 V Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord UK (75024)
ESA612-074132236ESA612 Switzerland, 230 V Includes all of the above items. Accessory Kit details: Alligator Clip Set (ESA T/L KIT EUR) Power Cord Switzerland (FBC-ESA620-4420)
ESA612-084132249ESA612 Thailand, 230 V Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord US with C19 Plug (75033)
ESA612-094132251ESA612 Japan, 100 V Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord USA (LINE CORD)
ESA612-104132260ESA612 North America, 220 V Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord US with C19 Plug (75033) Power Cord NA 220 V (75057) NA 220 V Adapter Kit (1800001)
ESA612-124161133ESA612-12-INDIA, 250V Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord INDIA
TA-ESA612-US4163288ESA612 US, 115 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) 15 – 20 A Adapter(2719-0154) Power Cord US (LINE CORD)
TA-ESA612-FR4163295ESA612 France/Belgium, 230 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord Europe (75026)
TA-ESA612-EUR4163301ESA612 Europe, 230 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord Europe (75026)
TA-ESA612-ISR4163312ESA612 Israel, 230 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord Israel (LINE CORD)
TA-ESA612-AUS4163320ESA612 Australian, 230 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord Australian (75025)
TA-ESA612-UK4163335ESA612 UK, 230 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord UK (75024)
TA-ESA612-SWI4163347ESA612 Switzerland, 230 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord Switzerland (FBC-ESA620-4420)
TA-ESA612-THAI4163358ESA612 Thailand, 230 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord US with C19 Plug (75033)
TA-ESA612-JAPAN4163364ESA612 Japan, 100 V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT USA) Power Cord US with C19 Plug (75033)
TA-ESA612-NA220V4163373ESA612 North America, 220 V with test automation Includes all of the above items. Accessory Kit details: Alligator Clip Set (ESA T/L KIT USA) Power Cord US with C19 Plug (75033) Power Cord NA 220 V (75057) NA 220 V Adapter Kit (1800001) Ansur Plug-in License CD (ANSUR ESA612)
TA-ESA612-INDIA4163399TA-ESA612-12-INDIA, 250V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord INDIA
ESA612-13-S AFRICA5261507ESA612-13-S AFRICA, 250V with test automation Includes all of the above items. Accessory Kit details: AC285 Alligator Clip Set (ESA T/L KIT EUR) Power Cord S AFRICA

Do not double-click an ESA612 Data Viewer .CSV file to open it in Excel if your computer is configured for a regional setting that does not match the US settings. You can configure the settings to match your regional setting as follows:

  • Rename the .CSV file to a .TXT file
  • Start Excel
  • Choose File/Open and set "Files of type" to All Files (*.*)
  • Select the desired .TXT file and press Open
  • On the first screen that appears you select "Delimited":

 

  • On the second screen you select "Comma":

 

  • On the next screen you click the "Advanced" button and change the Decimal separator to period "."

 

  • Click the Finish button and the file will be imported.

All electrical safety plug-ins power off, then apply a delay to ensure a minimum time with power turned off before turning it on again, in addition to letting the device under test (DUT) stabilize after powering off.

This is also consistent with the way the Power On Delay is implemented. The DUT power is switched on and then the delay is applied, allowing the DUT to stabilize after powering on.

If you want to perform any actions before powering a DUT on or off , you should use the "Stop before new power configuration" and/or "stop after new power configuration" options.

1 ) Printer is not based on PCL5 or ZPLII
2 ) Every time the device and printer are powered off or the printer is connected to another device the printer needs to be reset.

An example procedure to do so:

  • ESA615 Reset the printer by:
  • "Setup" -> F3 (printer settings) -> F1(Reset Printer)
Shopping Cart
Scroll to Top