LifeForce PS320 Fetal Simulator
The PS320 is a fetal monitor simulator that accurately tests and troubleshoots.
LifeForce PS320 Fetal Simulator
- Overview
- Models
The PS320 simulates fetal and maternal ECG, as well as uterine activity, to test and troubleshoot fetal electronic monitors and to train clinical staff.
The unit is battery operated and small enough to fit in a pocket so mobile technicians and clinical instructors can take it anywhere. The PS320 is a fetal monitor simulator that provides several fetal parameters including twins, and it simulates a wide range of clinical scenarios for training labor-and-delivery staff in how to recognize normal and abnormal responses. An optional mechanical heart creates fetal heart sounds for testing fetal monitors’ ultrasound cables and transducers. The Fluke Biomedical PS320 offers an easy user interface providing a 2 x 16-character LCD display with adjustable contrast. The unit operates on a 9-volt battery with low-battery monitoring or functions with the supplied battery eliminator.
Key Features
- Mechanical heart for ultrasound simulation
- TOCO simulation (External or IUP)
- Ultrasound simulation (including twins)
- Maternal ECG simulation
- Fetal ECG (tracks ultrasound #1)
- Internal (DECG) and external fetal ECG
- Uterine-activity selections
- Fetal beat-to-beat variability
- Periodic and non-periodic fetal ECG changes
- Arrhythmia selections
- Compact, lightweight, pocket-size plastic housing
- Battery operated with status indications
- Special kits available with all required accessories and cables to test fetal monitors for specified manufacturers
Model Name | Part Number | Description |
---|---|---|
PS320 | 2583030 | Fetal Simulator Includes: Electronic-version users manual (CD-ROM) Printed-version Users Manual (MANUAL) Battery eliminator universal 90 to 240 V (BE-UNVSL-IEC320C14) 9 V battery |
Kit #1: GE Corometrics | 2794057 | PS320 Fetal Monitoring Kit, GE Corometrics Includes: PS320 Fetal Simulator (PS320, includes Operator Manual MANUAL, Battery Eliminator BE-UNVSL-IEC320C14, and 9 V Battery) MFH-1 Mechanical Fetal Heart Probe –includes Fetal Heart Cable (17156) Soft-Sided Carrying Case for kit (ACCU LUNG CASE) RS-232 Cable, PS320/420 (17291) Corometrics Ultrasound Simulation Cable (17483) Corometrics IUP Simulation Cable (17481) Corometrics TOCO Simulation Cable (17486) Ultrasound Simulation Cable Series 120 (PN 4021537) |
Kit #2: Hewlett-Packard, Agilent, Philips Medical | 2794069 | PS320 Fetal Monitoring Kit, Series 50/8040 Philips Medical, Hewlett-Packard, Agilent Includes: PS320 Fetal Simulator (PS320, includes Operator Manual MANUAL, Battery Eliminator BE-UNVSL-IEC320C14, and 9 V Battery) MFH-1 Mechanical Fetal Heart Probe –includes Fetal Heart Cable (17156) Soft-Sided Carrying Case for kit (ACCU LUNG CASE) RS-232 Cable, PS320/420 (17291) HP/AG/PHILIPS (50 SERIES) Ultrasound Simulation Cable PS320 (17482) HP/AG/PHILIPS (50 SERIES) EXT TOCO Simulation Cable PS320 (17484) HP/AG/PHILIPS (50 &8040 SERIES) IUP Simulation Cable PS320 (17487) HP (8040 SERIES) Ultrasound Simulation Cable PS320 (17488) HP (8040 SERIES) EXT TOCO Simulation Cable PS320 (17489) |
Kit #3: Oxford Medical | 2794078 | PS320 Fetal Monitoring Kit, Oxford Medical Includes: PS320 Fetal Simulator (PS320, includes Operator Manual MANUAL, Battery Eliminator BE-UNVSL-IEC320C14, and 9 V Battery) MFH-1 Mechanical Fetal Heart Probe –includes Fetal Heart Cable (17156) Soft-Sided Carrying Case for kit (ACCU LUNG CASE) RS-232 Cable, PS320/420 (17291) OXFORD IUP Simulation Cable (17492) OXFORD Ultrasound Simulation Cable 2 MHz (blue) PS320 (17491) OXFORD Ultrasound Simulation Cable 1.5 MHz (yellow) PS320 (17490) |