ProSim SPOT Light SpO2 Pulse Oximeter Tester

15-second tester

The SPOT Light pulse oximeter tester is a lightweight and easy-to-use SpO2 functional tester. Preset programs test any combination of saturation, heart rate, perfusion, transmission, artifact noise, and R-curve in 15 seconds or less.

ProSim SPOT Light SpO2 Pulse Oximeter Tester

Lightweight, Easy-to-use Pulse Oximeter Tester

Featuring an exclusive ergonomic design, the ProSim SPOT Light is the first comprehensive SpO2 pulse oximeter functional tester to come in a handheld and easy-to-use device. SPOT Light is lightweight and flexible with three custom presets specially-designed to make it the fastest and easiest-to-use pulse oximeter analysis device on the market today for SpO2 functional testing. A helpful LCD display and three simple buttons make it effortless to rapidly change parameters and view each signal output sent to the pulse oximeter at a glance. An interchangeable, long-life battery ensures uninterrupted all-day operation without need to connect to a power supply. SPOT Light sets up in seconds to send Peripheral capillary oxygen saturation (SpO2), heart rate, perfusion, transmission, artifact noise, and eight different manufactures custom R-curves to a pulse oximeter or patient monitor. It is designed to take the abuse of everyday use, including the stresses of transportation, moving from room to room and device to device, and the occasional fall from the workbench. An increasing number of medical devices now have pulse oximetry built in. SPOT Light can be paired with other Fluke Biomedical test tools to make modern the modern pulse oximeter testing task fast and easy. Need to check a defibrillator with pulse oximetry? SPOT Light with the Impulse 7000 Defibrillator Analyzer allow you to test any external defibrillator on the market today. Do you have a fleet of new patient monitors coming that require incoming inspection? Using SPOT Light with ProSim 4 vital signs simulator allows you to easily accomplish this task in hours instead of days.

Key Features

  • Small, portable and lightweight
  • Large, easy to read LCD display
  • Rechargeable battery lasts 10 hours minimum
  • Signal strength indicator
  • SpO2 Saturation: 70%, 75%, 80 %, 85 %, 90 %, 95 %, 97 %, 98 %, 99 % and 100 %
  • Heart rate: 30, 40, 60, 65, 80, 100, 120, 140, 150, 180 and 240 BPM
  • Perfusion: 0.2 %, 2 % and 10 %
  • Transmission: dark/thick, normal and light/thin
  • Artifacts: respiration and ambient light
  • R-curves: Nonin, Masimo, Nellcor, Nihon Kohden, Mindray, GE, Philips, BCI
Model NamePart NumberDescription
SPOT Light4111101ProSim SPOT Light Device US Includes all of the above items as well as the Line Cord ProSim SPOT Line Cord (US).
SPOT Light4142735ProSim SPOT Light Device SCHUKO Includes all of the above items as well as the Line Cord ProSim SPOT Line Cord (Schuko).
SPOT Light4142747ProSim SPOT Light Device UK Includes all of the above items as well as the Line Cord ProSim SPOT Line Cord (UK).
SPOT Light4142758ProSim SPOT Light Device JAPAN Includes all of the above items as well as the Line Cord ProSim SPOT Line Cord (Japan).
SPOT Light4142764ProSim SPOT Light Device AUSTRALIA/CHINA Includes all of the above items as well as the Line Cord ProSim SPOT Line Cord (AUS/China).
SPOT Light4142814ProSim SPOT Light Device BRAZIL Includes all of the above items as well as the Line Cord ProSim SPOT Line Cord (Brazil).

With the pulse oximeter turned on, look for the visible red light coming from the probe. This side of the pulse oximeter finger probe must go on the SpO2 Test Module with a metal plate attachment.

Pulse oximeters use wavelengths of two lights (infrared light at 940 nm and red light at 660 nm), which are absorbed differently by either oxyhemoglobin or the reduced hemoglobin to measure arterial oxygen-saturation level (SpO2).

SaO2 read from a pulse oximeter is SpO2. This has become a standard in recent years.

1 count is equal to 1 % of SpO2 saturation. For example, if a customer tests Nellcor sensor at 95 %, he should expect the Nellcor monitor reads within "1 count" value which could be either 94 % or 96 % + accuracy of UUT.

Masimo Rainbow is the first technology to noninvasively measure blood constituents and fluid responsiveness that previously required invasive procedures. Besides measuring arterial oxygen-saturation level (SpO2) and pulse rate, Rainbow technology measures following parameters as well: Hemoglobin (SpHb), Carboxyhemoglobin (SpCO) and Methemoglobin (SpMet).

Traditional Pulse oximeters use wavelengths of two lights (infrared light at 940 nm and red light at 660 nm), which are absorbed differently by either oxyhemoglobin or the reduced hemoglobin to measure SpO2 concentration. Two-wavelength oximeters cannot measure total hemoglobin or dyshemoglobins. Rainbow sensor technology uses more than 7 wavelengths of light to acquire blood constituent data based on light absorption.